5號、4A號磚砌化糞池施工方案.doc
進入下載頁
1、工程概況
廠區位于開發區廠區總用地面積:25557平方米,排水管道選用DN200—DN400混凝土管道,抹帶接口。化糞池HC1選用標準圖集:98S7—138~151-5號磚砌化糞池,選用有地下水型,化糞池有效容積:30立方米;化糞池HC2選用標準圖集:98S7—121~137-4A號磚砌化糞池;有地下水型,有效容積:20立方米。
2、編制依據
①、《建筑地基基礎工程施工質量驗收規范》GB50202-2002;
②、《混凝土結構工程施工質量驗收規范》GB50204-2001;
③、《砌體工程施工質量驗收規范》GB50203-2002;
④、《建筑給水排水及采暖工程施工質量驗收規范》GB50242-2002;
⑤、《地下防水工程質量驗收規范》GB50208-2002;
⑥、公司廠區室外管網設計圖紙及選用標準圖集規定等;
3、施工措施
根據公司廠區地質勘察報告得知,廠區地下水位埋深較淺,而且按所選化糞池結構
1, Project Overview
Factory plant is located in Zone total land area: 25,557 square meters, sewer use concrete pipes DN200-DN400, wipe with interfaces. Use standard septic tank HC1 Atlas: 98S7-138 ~ 151-5 No. brick septic tank, use a water-based, effective septic tank volume: 30 cubic meters; septic tank use the standard HC2 Atlas: 98S7-121 ~ 137-4A No. brick septic tank; a water-based, effective volume: 20 m3.
2, prepared according to
①, "Building Foundation Construction Quality Acceptance" GB50202-2002;
②, "Concrete Structures for Construction Quality Acceptance" GB50204-2001;
③, "Masonry Construction Quality Acceptance" GB50203-2002;
④, "Building Water and Heating Engineering Quality Acceptance" GB50242-2002;
⑤, "Quality Acceptance of underground works" GB50208-2002;
⑥, company plant outdoor pipe network design drawings and atlas selection criteria requirements, etc.;
3, construction measures
According to geological survey reports that the company plant, plant shallow groundwater depth, and the septic tank structure according to the selected