        配電箱安裝施工要點

        (1)設備要求
        1)柜(盤)本體外觀檢查應無損傷及變形,油漆完整無損。柜(盤)內部檢查:電器裝置及元件、絕緣瓷件齊全,無損傷、裂紋等缺陷。
        2)安裝前應核對配電箱編號是否與安裝位置相符,按設計圖紙檢查其箱號、箱內回路號。箱門接地應采用軟銅編織線,專用接線端子。箱內接線應整齊,滿足設計要求及驗收規范(GB50303-2002)的規定。
        (2)作業條件
        配電箱安裝場所土建應具備內粉刷完成、門窗已裝好的基本條件。預埋管道及預埋件均應清理好;場地具備運輸條件,保持道路平整暢通。
        (3)配電箱定位:根據設計要求現場確定配電箱位置以及現場實際設備安裝情況,按照箱的外形尺寸進行彈線定位。
        (4)基礎型鋼安裝
        1)按圖紙要求預制加工基礎型鋼架,并做好防腐處理,按施工圖紙所標位置,將預制好的基礎型鋼架放在預留鐵件上,找平、找正后將基礎型鋼架、預埋鐵
        Distribution box installation and construction elements

        (1) Equipment requirements
        1) cabinet (disk) visual inspection body should be no damage and deformation, paint intact. Cabinet (disk) internal inspection: electrical equipment and components, complete insulation porcelain pieces, no damage, cracks and other defects.
        2) Before installation should check whether the distribution box number in line with the installation location, according to design drawings check the box number, box number loop. Door ground should be soft copper braided wire, special terminal. Box wiring should be neat to meet the design requirements and acceptance (GB50303-2002) requirements.
        (2) Operating conditions
        Distribution box installation sites within the civil engineering should have completed painting, doors and windows have been installed good basic conditions. Embedded pipe and embedded parts shall be cleared; site with transportation to keep the flow smooth.
        (3) distribution box Location: According to the design field position and field distribution box to determine the actual installation conditions, according to box dimensions for bomb line orientation.
        (4) basic steel installation
        1) The requirements of the drawings based on pre-processing of steel frame, and good corrosion protection, construction drawings are marked by location, type of prefabricated steel frame on the basis of a good reserve iron, the leveling, aligning steel frame will be based, pre- Underground Railway
         