銅芯電線電纜載流量標準IEC60364-5-523.doc
進入下載頁
目 錄
523.載流量 9
523.0 引言 9
523.1 一般要求 9
523.2 環(huán)境溫度 11
523.3 土壤熱阻率 12
523.4 多回路成組 13
523.5 有載導線根數(shù) 14
523.6 并聯(lián)導線 15
523.7 沿路線敷設條件的變化 15
表52-B1 敷設方式A至D一覽表 16
表52-B2 敷設方式E、F及G一覽表 18
表52-C1 按表52-B1中敷設方式的載流量(A) 20
表52-C2 按表52-B1中敷設方式的載流量(A) 21
表52-C3 按表52-B1中敷設方式的載流量(A) 23
表52-C4 按表52-B1中敷設方式的載流量(A) 24
表52-C5 按表52-B1中敷設方式C的載流量(A) 25
表52-C6 按表52-B1中敷設方式C的載流量(A) 26
表52-C7 按表52-B2中敷設方式E、F及G在自由空氣中的載流量(A) 27
表52-C8 按表52-B2中敷設方式E、F及G在自由空氣中的載流量(A) 28
表52-C9 按表52-B2中敷設方式E、F及G在自由空氣中的載流量(A) 29
表52-C11 按表52-B2中敷設方式E、F及G在自由空氣中的載流量(A) 30
表52-D1 空氣中環(huán)境溫度不等于30℃時的校正系數(shù) 31
表52-D2 地下環(huán)境溫度不等于20℃時的校正系數(shù) 32
表52-E1 多回路或多根多芯電纜成組校正系數(shù) 33
表52-E2 多回路校正系數(shù),電纜直埋地中 34
表52-E3 多回路校正系數(shù),電纜敷設在地中導管內(nèi) 35
表52-E4 多根多芯電纜成組校正系數(shù) 36
表52-E5 單芯電纜多回路成組校正系數(shù) 37
附錄A 第523節(jié)各表簡化方法舉例 38
表25-X1 載流量(A) 38
表25-X2 載流量(A) 39
表25-X3 多回路或多根多芯電纜成組校正系數(shù) 40
附錄B 表示載流量的公式 41
系數(shù)和指數(shù)表 41
CONTENTS
523. Carrying capacity 9
523.0 Introduction 9
523.1 General requirements 9
523.2 ambient temperature of 11
523.3 soil resistance rate of 12
More than 523.4 Circuit Group 13
523.5 root number 14 wire-load
523.6 15 parallel wires
523.7 along the line, change 15 the conditions laid
Laying the table 52-B1 16 A to D list
Table 52-B2 laying methods E, F and G List of 18
Table 52-C1 by Form 52-B1 in laying the way carrying capacity (A) 20
Table 52-C2 in Table 52-B1 in laying the way carrying capacity (A) 21
Table 52-C3 by Form 52-B1 in laying the way carrying capacity (A) 23
Table 52-C4 by Form 52-B1 in laying the way carrying capacity (A) 24
Table 52-C5 by Form 52-B1 in the way of laying the carrying capacity C (A) 25
Table 52-C6 in Table 52-B1 in the way of laying the carrying capacity C (A) 26
Table 52-C7 by Form 52-B2 in the laying methods E, F and G are set out in the free air flow (A) 27
Table 52-C8 by Form 52-B2 in the laying methods E, F and G are set out in the free air flow (A) 28
Table 52-C9 by Form 52-B2 in the laying methods E, F and G are set out in the free air flow (A) 29
Table 52-C11 in accordance with Form 52-B2 laying methods E, F and G are set out in the free air flow (A) 30
Table 52-D1 is not equal to the air temperature 30 ℃, the correction factor of 31
Table 52-D2 does not mean ground temperature 20 ℃, the correction factor of 32
Table 52-E1 multi-loop or multi-core cable group root correction factor of 33
Table 52-E2 multi-loop correction factor, cable buried in the 34
Table 52-E3 multi-loop correction factor, cable laid in the duct 35
Table 52-E4 of multiple multi-core cable group correction factor of 36
Table 52-E5 group, single cable multi-loop correction factor of 37
Section 523 Appendix A simplified method for example 38 different tables
Table 25-X1 carrying capacity (A) 38
Table 25-X2 carrying capacity (A) 39
Table 25-X3 multi-loop or multi-core cable group root correction factor of 40
Appendix B that the formula contained 41 traffic
Coefficient and index table 41