普通燈具安裝工藝標(biāo)準(zhǔn).doc
進(jìn)入下載頁
普通燈具安裝工藝標(biāo)準(zhǔn)
總則、術(shù)語符號及基本規(guī)定參見5不間斷電源安裝。
11.1 施工準(zhǔn)備
11.1.1 技術(shù)準(zhǔn)備
(1) 施工前應(yīng)進(jìn)行技術(shù)交底工作;
(2) 配備相應(yīng)的施工質(zhì)量驗收規(guī)范。
11.1.2 材料設(shè)備要求
(1) 注意核對燈具的標(biāo)稱型號等參數(shù)是否符合要求,并應(yīng)有產(chǎn)品合格證,普通燈具有安全認(rèn)證標(biāo)志。
(2) 照明燈具使用的導(dǎo)線其電壓等級不應(yīng)低于交流500V,其最小線芯截面應(yīng)符合規(guī)定。
(3) 采用鋼管作為燈具的吊管時,鋼管內(nèi)徑一般不小于10mm。
(4) 花燈的吊鉤其圓鋼直徑不小于吊掛銷釘?shù)闹?br />
General lighting standard installation process
General principles, terminology and basic provisions of symbols see 5 uninterruptible power supply installation.
11.1 Construction preparation
11.1.1 Technical Preparation
(1) the classification of components should be carried out before construction work;
(2) with the corresponding acceptance of construction quality.
11.1.2 The material and equipment requirements
(1) Note that the nominal model matching parameters such as lighting for compliance and should have product certification, general lighting a safety certification mark.
(2) lighting wire the voltage levels used in exchange should not be less than 500V, the minimum wire core section shall comply with requirements.
(3) using steel as a hanging lamp tube, steel pipe inner diameter is generally not less than 10mm.
(4) lantern hook the round bar diameter is not less than hanging straight pin